+(86) 13866126226
hfchengchi@163.com

Tags for: temperature controller

Relationship between industrial furnace temperature rise and electric energy conversion

Relationship between industrial furnace temperature rise and electric energy conversion

industrial electric furnace starts to heat up, the brickwork in the furnace absorbs a large amount o... (more…)

Comparison and application of cooling performance of water, brine, caustic soda aqueous solution and sodium carbonate aqueous solution

Comparison and application of cooling performance of water, brine, caustic soda aqueous solution and sodium carbonate aqueous solution

The use of low concentration sodium carbonate aqueous solution is the same as that of sodium chlorid... (more…)

Brief Analysis of Common Regulating Law for Automatic Control of Heat Treatment Temperature in Industrial Electric Furnace

Brief Analysis of Common Regulating Law for Automatic Control of Heat Treatment Temperature in Industrial Electric Furnace

the temperature control of industrial electric furnaces and ovens is very important for heat treatme... (more…)

Cooling Characteristics of Sodium Carbonate Aqueous Solution

Cooling Characteristics of Sodium Carbonate Aqueous Solution

The relationship between the cooling capacity of the sodium carbonate aqueous solution (mass fractio... (more…)

Resistance furnace daily repair and maintenance experience

Resistance furnace daily repair and maintenance experience

ordinary heat treatment resistance furnace processing technology is mostly concentrated at the tempe... (more…)

Physicochemical characteristics of sodium carbonate aqueous solution

Physicochemical characteristics of sodium carbonate aqueous solution

The solubility of sodium carbonate in water, the density of sodium carbonate aqueous solution, and t... (more…)

Cooling characteristics of aqueous sodium hydroxide solution

Cooling characteristics of aqueous sodium hydroxide solution

 The maximum cooling rate of 15% NaOH aqueous solution is about 2600 ℃/s (higher than brine), the co... (more…)

Cooling rate curves of 10% and 20% sodium chloride aqueous solutions at different temperatures

Cooling rate curves of 10% and 20% sodium chloride aqueous solutions at different temperatures

The concentration of NaCl aqueous solution has a significant impact on the cooling characteristics.... (more…)

Cooling capacity of aqueous sodium chloride solution

Cooling capacity of aqueous sodium chloride solution

The cooling characteristics of sodium chloride aqueous solution and the effect of solution concentra... (more…)

Influence of Workpiece Quality and Size on Water Quenching Cooling Curve

Influence of Workpiece Quality and Size on Water Quenching Cooling Curve

The cooling curves of different masses (weights) and sizes in quenching tank are shown in the figure... (more…)