The test uses 2 liters of 60°C quenching oil, and the initial temperature of the probe is 850°C.The... (more…)
electric furnace the probe of the oscilloscope needs to adjust the impedance matching part before us... (more…)
According to the plotted temperature-time function relationship, as described in calibration, correc... (more…)
The measurement system shall be capable of providing a permanent record of the cooling performance o... (more…)
The time for the probe to move from the furnace to the container should not exceed 2 seconds. The re... (more…)
Cylinder as shown in the figure, alloy tube with nickel support thermocouple and geometric center. T... (more…)
quenching medium cooling performance experimental device consists of container, probe, heating equip... (more…)
Table Calibrating the cooling performance of the quenching fluidCooling performance Minimum Maximu... (more…)
The technical requirements and storage requirements for calibration quenching fluid used for probe c... (more…)
A cylindrical nickel alloy specimen (probe) with a thermocouple in the geometric center is heated to... (more…)