in the process of using FEROQUENCH2000 quenching fluid, the take-out consumption of quenching fluid
the take-out consumption of FEROQUENCH2000 quenching fluid
in the process of using FEROQUENCH2000 quenching fluid, the take-out consumption of quenching fluid is proportional to the concentration and the temperature of the part, FEROQUENCH2000 the higher the concentration of quenching fluid, the greater the take-out loss; and the higher the temperature of the part, the greater the take-out amount on the surface of the part.
therefore, with the deepening understanding of the performance characteristics of FEROQUENCH2000 quenching fluid, the use concentration has been reduced from the initial 10% ~ 12% to the range of 8% ~ 10%. At the same time, the operator is also strictly required to operate according to the specified production rhythm to ensure that the parts can be cooled to liquid temperature after the liquid, thus effectively reducing and controlling the consumption of quenching liquid.
according to the statistical results of actual production, a total of more than 3000 tons of crankshafts have been processed in actual production. on average, the FEROQUENCH2000 consumption for each processed It crankshaft is 1.6~2.0kg, which is basically equivalent to the cost of using no. 32 engine oil.
More Take-out consumption of using FEROQUENCH2000 quenching liquid: www.quenchtank.com/view-403.html